An OR logic control in pneumatic systems is possible with the help of

This question was previously asked in
ESE Mechanical 2018 Official Paper
View all UPSC IES Papers >
  1. sequence valve
  2. shuttle valve
  3. dual pressure valve
  4. delay valve

Answer (Detailed Solution Below)

Option 2 : shuttle valve
Free
ST 1: UPSC ESE (IES) Civil - Building Materials
20 Qs. 40 Marks 24 Mins

Detailed Solution

Download Solution PDF

OR Function

  • The single-acting cylinder in Fig can be operated by two different circuits.
  • Examples include manual operation and relying on automatic circuit signals, that is, when either control valve or control valve is operated, the cylinder will work.
  • Therefore, the circuit in Fig. possesses the OR function. However, if the output of two 3/2 directional control valves is connected through the port of a triode, the air current from the control valve will be released through the exhaust of the control valve, and so the cylinder will not work.
  • This problem can be solved by connecting a shuttle valve to the port of the triode. Shuttle valve allows fluid flow from one of two sources just like OR logic. The basic structure of a shuttle valve is like a tube with three openings.

Latest UPSC IES Updates

Last updated on May 28, 2025

->  UPSC ESE admit card 2025 for the prelims exam has been released. 

-> The UPSC IES Prelims 2025 will be held on 8th June 2025.

-> The selection process includes a Prelims and a Mains Examination, followed by a Personality Test/Interview.

-> Candidates should attempt the UPSC IES mock tests to increase their efficiency. The UPSC IES previous year papers can be downloaded here.

Hot Links: teen patti download apk teen patti comfun card online teen patti real money app rummy teen patti